Flexel EcoFlex In-Screed U/floor Heating Cable-160

Flexel EcoFlex In-Screed U/floor Heating Cable-160 - Area to be Heated -  1.3m2 - 200W Output
Showing Flexel EcoFlex In-Screed U/floor Heating Cable-160 - Area to be Heated - 1.3m2 - 200W Output
£37.28

Area to be Heated - 1.3m2 - 200W Output

Part No: 15200
Cable Length 13.7m
£44.57

Area to be Heated - 2.0m2 - 340W Output

Part No: 15340
Cable Length 22.0m
£50.85

Area to be Heated - 2.6m2 - 420W Output

Part No: 15420
Cable Length 28.0m
£59.51

Area to be Heated - 3.5m2 - 550W Output

Part No: 15550
Cable Length 37.0m
£64.42

Area to be Heated - 4.2m2 - 660W Output

Part No: 15660
Cable Length 45.0m
£71.60

Area to be Heated - 4.9m2 - 800W Output

Part No: 15800
Cable Length 52.0m
£78.11

Area to be Heated - 5.5m2 - 880W Output

Part No: 15880
Cable Length 59.0m
£83.16

Area to be Heated - 6.0m2 - 960W Output

Part No: 15960
Cable Length 64.0m
£91.21

Area to be Heated - 6.7m2 - 1070W Output

Part No: 151070
Cable Length 72.0m
£94.75

Area to be Heated - 7.6m2 - 1210W Output

Part No: 151210
Cable Length 81.0m
£99.52

Area to be Heated - 7.9m2 - 1300W Output

Part No: 151300
Cable Length 84.0m
£122.99

Area to be Heated - 9.8m2 - 1580W Output

Part No: 151580
Cable Length 105.0m
£145.14

Area to be Heated - 12.0m2 - 1900W Output

Part No: 151900
Cable Length 129.0m
£161.86

Area to be Heated - 14.0m2 - 2200W Output

Part No: 152200
Cable Length 150.0m
£214.38

Area to be Heated - 17.7m2 - 2800W Output

Part No: 152800
Cable Length 189.0m
£275.56

Area to be Heated - 21.4m2 - 3400W Output

Part No: 153400
Cable Length 228.0m

Product Reviews

Write a review
Flexel EcoFlex In-Screed U/floor Heating Cable-160

Flexel Ecoflex 160W/m2 Underfloor Heating Cable

Ecoflex in-screed underfloor heating cables have a rating of 15W/linear metre and are an economical solution for new screed floor constructions.

The first step is to determine the number of W/m2 that you require for your installation - this could be provided by calculating the heat losses from the room you intend to heat. This figure will depend on the standard of insulation in the building.

Before commencing, the entire sub-floor should be swept clean and be free from any sharp objects. If laying onto foil backed insulation ensure the area is dust free to enable a good fix. It is good practice to plan your installation using a sketch marking your laying pattern and planning the positions for the floor sensor, the connection box and thermostat.

Attach the Eco-Fix band to the sub-floor or insulation using fixing nails or high impact adhesive tape. The Eco-Fix bands should be spread evenly accross the floor at intervals of 750mm. A 75mm border should be left around the perimeter of the room. Do not remove the cable from the drum before laying as it will twist and make the installation difficult. The heating cables (orange cables) must not touch each other and should never cross. The heating cable must not be cut or shortened and the joint between the cold tail and the heating cable must not be bent or put under strain.

The floor sensor for the thermostat should be positioned between 2 heating cables approximately 500mm from the wall. The black flexible conduit provided should always be used to install the floor sensor probe. Once laid the heating cable should be covered with a minimum of 50mm sand and cement screed. Before, and after, covering the heating cable with the screed, the cable resistance should be checked against the label value. Avoid traffic over the areas until the cable is completely protected. The screed should be allowed to dry completely before turning on the system. Please check screed manufacturers instructions.

A fully qualified electrician must now make the final connections to the mains supply and install the thermostat. The thermostat should be installed in the room to be heated. For bathrooms the thermostat will be a floor sensing only model and must be placed outside the room but as close to the installation as possible. Finally the electrician should check for continuity of the floor sensor and retest the resistance of the cable. A further insulation test should be carried out in accordance with IEE regulations. The installation should be protected by a 30mA RCD for safe operation.